CJMYT - STAINAWAY, 14845

  • MSDS: CJMYT
  • Manufacturer: ECOLAB INC
  • Product Name: STAINAWAY, 14845
  • National Stock Number: 7930-00N091651
Product Identification

Product ID:STAINAWAY, 14845
MSDS Date:04/07/1992
FSC:7930
NIIN:00N091651
Status Code:A
MSDS Number: CJMYT

Responsible Party
ECOLAB INC
ECOLAB CENTER
ST PAUL, MN 55102
US

Emergency Phone: 800-328-0026

Info Phone: 800-352-5326

Cage: 85884

Contractor
ECOLAB PROFESSIONAL PRODUCTS DIVISION OF ECOLAB INC.
ST PAUL, MN 55102 US

Telephone: 800-352-5326

Cage: 85884

Ingredients

NONYLPHENOL ETHOXYLATE

CAS: 9016-45-9

RTECS: AX0247000

Hazards

Routes of Entry: Inhalation:NO Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES: CAUSES IRRITATION. SKIN: MAY
CAUSE IRRITATION, DEPENDING UPON DEGREE OF EXPOSURE. INGESTION: CAN
CAUSE IRRITATION, NAUSEA, STOMACH DISTRESS.
Effects of Overexposure:SEE HEALTH HAZARD.

First Aid

First Aid:EYES: FLUSH IMMEDIATELY WITH PLENTY OF COOL RUNNING WATER.
REMOVE CONTACT LENSES. CONTINUE FLUSHING FOR 15 MINUTES. SKIN:
FLUSH SKIN WITH PLENTY OF COOL RUNNING WATER. WASH THOROUGHLY WITH
SOAP AND WA TER. INGESTION: RINSE MOUTH; THEN DRINK 1 OR 2 LARGE
GLASSES OF WATER. DO NOT INDUCE VOMITING. NEVER GIVE ANYTHING BY
MOUTH TO AN UNCONSCIOUS PERSON. IF IRRITATION OR DISCOMFORT
PERSISTS, CALL A PHYSI CIAN.

Fire Fighting

Flash Point Method:PMCC
Flash Point:=173.9C, 345.F
SUPDAT
Extinguishing Media:USE FOG, FOAM OR FINE WATER SPRAY.
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .

Accidental Release

Spill Release Procedures:DIKE OR DAM LARGE SPILLS. PUMP TO CONTAINERS
OR SOAK UP ON INERT ABSORBENT. FLUSH RESIDUE TO SANITARY SEWER.

Handling

Handling and Storage Precautions:KEEP OUT OF REACH OF CHILDREN.

Exposure Controls

Respiratory Protection:USE NIOSH APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:EYEWASH AND DELUGE SHOWER MEETING ANSI
DESIGN CRITERIA .
Work Hygienic Practices:NO REQUIREMENTS BEYOND STANDARD INDUSTRIAL
HYGIENE PRACTICES.
Supplemental Safety and Health
FLASH POINT METHOD: PMCC: 173.9 C, 345 F. COC: 187.8C, 370 F.

Chemical Properties

Boiling Pt:>204.4C, 400.F
Spec Gravity:1.025-1.300
pH:NA(NON-AQUEOUS)
Solubility in Water:INSOLUBLE
Appearance and Odor:WATER WHITE TO AMBER CLEAR LIQUID, MILD ORGANIC
ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
DIRECT CONTACT WITH STRONG OXIDIZING AGENTS CAN CAUSE RAPID REACTION.
Stability Condition to Avoid:DO NOT MIX WITH ANYTHING BUT WATER.

Disposal

Waste Disposal Methods:CONSULT FEDERAL, STATE AND LOCAL AUTHORITIES FOR
RESTRICTIONS ON DISPOSAL OF CHEMICAL WASTE.

Transport

Transport Information:DOT SHIPPING DESCRIPTION: PETROLEUM DISTILLATE,
N.O.S., COMBUSTIBLE LIQUID. UN 1268. III. NOTE: IN CONTAINERS OF
119 GALLONS CAPACITY OR LESS THIS PRODUCT IS NOT REGULATED BY DOT.

Regulatory

SARA Title III Information:UNDER PROVISIONS OF TITLE III, SECTIONS
311/312 OF THE SUPERFUND AMENDMENTS & REAUTHORIZATION ACT, THIS
PROD IS CLASSIFIED INTO FOLLOWING HAZ CATEGORY: FIRE. THIS INFO MAY
BE SUBJECT TO PROVISIONS OF COMMUNITY RIGHT-TO-KNOW REPORTING REQS
(40 CFR 370) IF THRESHOLD QTY CRITERIA ARE MET. THIS PROD DOES NOT
CNTN SECTION 313 REPORTABLE INGREDS.
Federal Regulatory Information:PROD IS HAZ AS DEFINED IN 29 CFR
1910.1200. OSHA HAZ: COMBUST. PROD IS LISTED ON TSCA INVENTORY AT
CAS #64742-47-8. PROD IS CLASSIFIED AS OIL UNDER SECTION 311 OF
CLEAN WATER ACT (40 CFR 110) & OIL PO LLUTION ACT OF 1990.
DISCHARGE/SPILLS WHICH PRDCE VISIBLE SHEEN AT EITHER SURF WATER OR
IN WATERWAYS/SEWERS WHICH LEAD TO SURF WATER OR IN WATERWAYS/SEWERS
WHICH CAN LEAD TO SURF WATER, MUST BE REPORT ED TO NRC AT
800-424-8802. IF PROD IS ACCIDENTALLY SPILLED, IT IS NOT SUBECT TO
ANY SPECIAL REPORTIN G UNDER REQS OF COMPREHENSIVE ENVIRONMENTAL
RESPONSE COMPENSATION & LIABILITY ACT (CERCLA). (ECOLOGICAL INFO)
State Regulatory Information:OTHER INFO: SINKING &/OR SUITABLE
DISPERSANTS MAY BE USED IN NON-CONFINED WATERS. CONSULT EXPERT ON
DISP OF RECOVERED MATL & ENSURE CONFORMITY TO LOC DISP REGS.
HNDLG/STOR: SOURCES OF IGNIT. PROTECT M ATL FROM DIRECT SUNLIGHT.
MATL WILL ACCUMULATE STATIC CHARGES WHICH MAY CAUSE ELEC SPARK
(IGNIT SOURCE). USE PROPER GROUNDING PROCS. DO NOT PRESSURIZE, CUT,
HEAT OR WELD CNTNRS. EMPTY PROD CNTNRS MAY CONTAIN PROD RESIDUE.
DO NOT REUSE EMPTY CNTNRS W/OUT COMMERCIAL CLEANING OR
RECONDITIONING.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.